Environmental Advisory Board Meeting
Town of Apex ·
Environmental Advisory Board
Wednesday, October 7, 2026 at 12:00 pm
Agenda document Meeting page Watch Meeting recap
What's on this agenda
Noise from data centers is the only business on this agenda. Bruce Venable, a Planner III, gives a presentation on noise impacts to the Environmental Advisory Board's Data Center Subcommittee, which meets at 5:00 PM in Council Chambers at Apex Town Hall.
The agenda describes the subcommittee's job as gathering information on data centers and working on the related amendments to the Unified Development Ordinance. It lists five members and no public comment period.
Summarized from the published agenda. Read the agenda itself before acting on it.
Meeting recap
What happened, drawn from the records published after the meeting. Recording
Venable walked the subcommittee through where data center noise comes from and an early draft of noise rules for the Unified Development Ordinance. He called the draft a working document that no other department had reviewed. He gave typical levels of 80 to 100 decibels for substations, 80 to 95 for air-cooled chillers and 95 to 105 for diesel generators in the open. He said the usual A-weighted measurement misses the low-frequency hum that runs around the clock. The draft adds C-weighted and one-third-octave-band measurement and continuous monitoring, and the town would choose an independent acoustic consultant paid for by the applicant. Venable said the draft draws on Prince William County's updated ordinance, a proposed South Carolina bill and Colorado's oil and gas noise rules. He said the bracketed figures, including setbacks of 500 to 1,500 feet by tier, are placeholders and will change. He also took out the South Carolina bill's fines, which run $10,000 to $35,000 a day, until the town's lawyers say what North Carolina allows.
Members said some of the draft decibel limits were too high for noise that never stops. They also asked about generator testing notices, vibration and water use during a drought. Members asked staff to try to get a copy of ASHRAE Standard 90.4, the data center efficiency standard, which costs $178. Staff said the draft came early because two members leave in January. Residents were to give their views at a neighborhood meeting on the 14th, and next month's meeting was to cover public safety with fire and police. The meeting closed at 6:29. These notes come from auto-generated captions that are badly garbled, so the figures are approximate.
Full transcript
Automatic captions from the recording, "2026.10.07 Data Center Subcommittee Meeting". Runs 1 hr 44 min. These are machine transcriptions, not a court record. They misrender names and figures — "Kildaire" comes through as "kill dare", and case numbers arrive as noise. Each timestamp opens the video at that moment, which is how a passage here gets checked against what was said.
Read the transcript (46 passages)
Oh, congratulations. Oh, exactly. Yes. Thank you. Thank you.
I announce the meeting. subcommittee on processing centers data from October 7 open, now, when we installed quorum, welcome everyone from return. AND let's go right away Let's get down to business. Tonight we Let's talk about noise. This is so deviant, but they stuck it here sticker with a request to stand before this tribune during performance. It's simple. it was necessary. It funny. Because people naturally become here here. OK. Therefore, Good evening, members. subcommittee. Pleasantly to see you all again . Nice to see new members who joined us, Kimberly and Ramesh. We have already spent several meetings before this time. Next meeting with our series will be dedicated to noise: how noise is created influence in the centers data processing and how it can be mitigated . In addition, before you are lying enough large-scale project noise regulations, related to processing centers data. This is just working document. He has not yet been checked no others departments or someone else. It's simple. way to understand wishes and needs subcommittee to to provide a certain direction of work. This information will be posted on the network later after presentations, and now We will begin. Therefore, let's make a short one overview of the topic of noise. We let's talk about types and noise sources in processing centers data. So, speaking about types of noise, I want immediately warn, and This is probably obvious, that I am not an engineer, not mathematician and not specialist in these complicated things. Ago I will do my best. to explain to you some points in simple language. So, if any arise questions that I don't know the answers to I can answer, I am from I will be happy to contact you. someone who can help you answer. But we let's try to deal with this best of luck, thanks our common experience in this room. So, about the types of noise: there are different hertz, frequencies and ranges, which in general make noise. Human range perception is from 20 to 20,000 hertz, as you can see here on the screen in front of you or on yours monitors. There is Infrasound is a sound, which is too low,
so that we can have it hear, but we all we can do the same to feel it physically. And there is also ultrasound, which also goes for the limits of our normal range hearing, but maybe to be used in various fields and aspects. Today we let's focus more on infrasound, because he can to be created large equipment and other powerful sources on objects that are of a certain as far as it concerns this center, so we briefly about it Let's remember. And what? concerns planning and options land use, and especially municipal regulations on the level noise, most of these resolutions over the last 50 years focused on the ranges decibel, namely on weighted A scale, which focused on a person. This graphic simply illustrates how looks like scale A. It covers all hertz, takes into account different frequencies and ranges, providing a balanced measurement, but actually filters out all low-frequency noises, which people usually don't perceive. So in it there are definitely certain disadvantages. Because such appear objects like hyperscale data centers, and they are located closer to residential areas districts, municipalities start more often use measurement by scale S. She takes into account a little broader general frequency range. But sometimes it doesn't matter is missing, we are talking about this let's talk a little later. Needed to delve into detail in the sound level in octave bands, considering each a separate lane to to understand exactly where noise is generated. After all sometimes you can create a lot noise at low frequencies, but this is not will be displayed if you spend A- weighted measurement device on the site. Therefore, let's consider the general processing center diagram data and where it comes from noise may occur. IN We have substations that can create low humming, sounds medium and low high frequency. Obviously, there will be HVAC systems and ventilation installations. Will be generators, cooling towers,
air coolers and all that other stuff will create different noise level depending on from the general working load. But regarding processing centers data is worth remember that, especially in the case of hyperscale centers that we are talking about they said, they working with level reliability "five" "nines". They always functioning. They work in 24/7 mode. So, this is to some extent that distinguishes this object from others industrial users who also have equipment that makes noise, but they usually have certain hours work, if not it's about something specific. So, I I'll quickly walk around. these points. Some of I've seen you before. materials earlier. So, the noise from substations. Again yes, he can generate from 80 to 100 decibel on the A scale. In I have a small one. illustration to to show that this hum, this low frequency noise, there is enough dominant in range from 20 to 200 Hz, and then he starts to reach a little higher frequencies than scale A, within human hearing. They can be very big when it's about date- centers like the one that was proposed here, or others who are offered now and is significantly larger scale. These objects are forced to build such substations on its own territories, they can be huge and themselves create for themselves quite a bit of noise. We talked about settings for air treatment. Here about like them look. They can be placed directly on the territory of the object for air circulation. They can be installed in different places: on the roof, on land, anywhere, wherever this is necessary. They can also generate low-frequency noise. We also talked about air-cooled chillers cooling. This is still one illustration. They produce various frequencies coming from different parts of itself machinery. In particular, from lower parts can go medium or high pitched sound, and from fans that blow air up, —low and medium frequencies. A significant part low frequencies generated by movement air and equipment for cooling on the playground—this concerns fans and something like that. Reserve generators obviously are also serious noise sources. It also has a significant
value. I don't know whether Have you heard the news, but many data centers are now running from own systems generations electricity on place. According to their way use if they use diesel generators for power, this means that they work a lot more often than not for backup power supply or short-term using. Such way, depending on the nature of the work, they are potentially create a wide frequency spectrum noise on the site. Again, cooling towers. Considering a large number fans and equipment that passes through them air, they also create a lot noise, which we already mentioned remembered. Here are some typical decibel levels for such objects. So, diesel generators can give out from 75 to 85 decibel indoors condition and from 95 to 105, when they are open. Air coolers—we we expect 80-95. Cooling towers—from 70 to 90 decibel. And so on. Um, you can. see the substation, where the noise level is about 60-80 decibel. This is the range, within which all these were held measurement. And also construction noise, traffic and supply fuel. So all these things, many of them will operate simultaneously on any the site. You have many areas from where there is a loud noise, and it takes a lot effort and attention to try minimize or prevent this. Therefore , the reason why the date- the center is different, what are we talking about in part mentioned, is in because it is permanent noise 24/7 for most these objects really affects people who, maybe they don't hear him when they are on at work, away or at school, but when they come home and are trying to rest or to spend time with family, this constant noise is present, and this can be very harmful to their health. We talked. about generators and low-frequency noises, and about how they can also be on them influence. Therefore, talking a little about best ways management of this and why these problems arose— dBA scale, obviously, doesn't even catch many of these lower frequencies. This is not
checked and not measured. But even when you using dBA and DBS, sometimes it doesn't matter remains gap. And exactly so, um, you'll see, when will you review part of the materials before you regarding proposed changes to UDO, um, there actually it is about use of all three or about application 1/3 octave band, which allows you to see more more detailed version noise that generated for each frequency band. Um, we should too to consider when we are talking about the noise that weather and temperature can also be on it influence. Um, I don't. expert in this, but, essentially, the wind is behind the wind can help move noise and to spread it. Temperature can adjust the spread noise, relative humidity too plays its role. So this is also what need to consider at any modeling or, um, testing. You really need to conduct testing on a clear day when there is no potential for wind, weather conditions or something else that could give false positive or false result. So, there are a few things, um, some of them were kindly provided or handed down to us, um, residents of the city. I I think that was it. very interesting. We a lot was said about Prince William County in Virginia. Um, that was it. research report noise from the centers data processing, prepared Doctor of Philosophy John Lever. He, seems to have been a member the county commission, and also taught at George University Mason. He has quite big work experience. Of course , I didn't have criteria to really to evaluate or judge John's material, but I I thought it was wonderful. thing to get acquainted with, to get idea of the whole the work he has done. This will be posted on website and sent to you after this meeting so that you could get acquainted with them in their free time. So, he investigated all these different little things territory and studied their. He tried to predict which there will be noise level after full development of centers data processing and how it will grow in depending on territory. So, he considered all these different zones. Worth it to note that in summary tables he too analyzed local ordinances regarding noise, particularly in Prince William County. He wanted to see,
what percentage considered by him territories actually would violate current noise standards, if they were were completely built-up. In accordance with its results and research seems to that almost everyone, except two, 100% violated b own noise standards, which were in force at that time. So, despite the best intentions, you had noise ordinance and wanted people to adhered to, but different things happen, and, unfortunately, unpredictable circumstances in such a at a fast pace, probably led to problems with this. Again anyway, in this table six is considered a little more detail. Current noise level with added centers data processing, and also coefficient increase and nearest centers data processing and their streams. Here you can to see how far are these data centers and how much it doesn't matter the total will increase noise level. So, on at the very beginning, in clubhouse, the indicator increases from 50.5 to a potential 68.7. It quite significant jump. This is a big the amount of noise that is generated. Can to see that in some In some places the level reaches 70 decibel due to work equipment, even if they are very far. So, they create a lot noise in general, and about this It's worth knowing because he created wonderful illustrations and maps, which, I'm sure, I I'll show you now. In red all marked center buildings data processing that working together now with road noise. So, this is taken to attention. And then clean noise level after buildings. So this is, uh, modeled and provided. Again yes, you can to see how much additional noise create some of these objects. Here, for example, district Carter Wood, where is it now? noise level is about 44.1, It's very quiet there. Uh, and then it grows to 65. This is quite tangible the change that people, will probably notice. Um, you know, the usual conversation is approximately 60 decibels. But when this is happening jump, he starts to feel everything louder, louder and louder. Here's another one another example a small area, which he considered, with predicted noise intensity. Again, this is just forecasts, so here there may be certain nuances, but that's all It's still interesting. Again Yes, you see that even on such a
distances, like some of them, and this in some cases almost a mile, anyway observed very significant increase noise from data centers compared with initial level. Again, here it is again one example date- centers near Brick- Yard. And you can see, what if built only data center buildings on Brick Yard Way, general level The noise would increase a little, but at full we are building we get an increase of more by 2.5, well a little less 2.5 decibels in these districts. So, this is significant contribution. And I I think they are are trying to do everything is possible with your own resolutions on noise level, but it is obvious that the volumes and the amount of this infrastructure that under construction, simply difficult to calculate. AND I think most local municipalities not have expert knowledge or personnel, ready-made, proper way to model these things. Hmm, another one example here. All this will be provided to you, so that give a good idea about the necessary distance and how noise...Oh. So, in his report, he is very long. Sorry, that's why I didn't print it. its for you today . Uh, he really had resume and recommendations. Its the resume contained appeal to the government Prince William County better to do your obligations regarding protection residents by obtaining reliable noise forecasts for these proposed projects, as well as to that the North Virginia must find better opportunities and more qualified staff to to provide protection residents of cities and districts. So, they really provided here recommendations. Ahem, they are not very specific. It's simple. things like necessity modernize our regulations on the level noise to take in this participation. Yes, no very specific, but I I would like to note that the district Prince William took it note, updated noise ordinance May of this year and changes some things. One of the things they do—this is a consideration several zones of influence, to see where from these problems come from. They increase distance and also canceled a lot buildings that were carried out by
simplified procedure . So, they trying to move in the right way direction, but... Are they trying? solve...the problem that several processing centers data are located nearby and reinforce this noise? Yes, right there. I think I will have to to people like us who have there are no active ones data, have opportunity to see their mistakes and work on this. I not sure, but I hope so, because they already have a lot built, and they need to do this, but as you can see, we are talking about a complete development. This is not what we do not allow— maybe not we allow gradualism, and then we would have to consider all of them types of use with reduction plan noise. And those resolutions that they reinforce, don't they they are used retroactively? Usually not. That is, for any new buildings can be rules, and in each they are a little bit in the state differ in terms of of what can be done. If we now have inappropriate use, all will depend on complaints and what we can do apply, but if they were approved and already working, then very it's hard to change something, although sometimes it is helps. Sometimes can I talk to you? neighbors, and this can certain dates results. This is also depends on to whom are given powers. Is this police powers ? Is this a power of attorney? planning authorities? Yes, I am a little confused, you said that when centers data processing are being built completely, they exceed noise standards. How are they Can they do this? I I'm sure they are. receive permission to a certain amount buildings, but if... then all this has to fall under general resolution about the noise. Mm. That's right. I have on mean, what they received permission to building a bigger one volume, does not mean that they must either can do it. Yes, part of the problem in that many jurisdictions in general did not take into account noise level that is added to the district. They only looked at what was required under the time of application, and
considered this. Often It happens that when complex ones are coming or difficult for understanding reports from some engineer, they put their seal and claim that this truth. One interesting one fact about John's report is that he checked the data center Amazon acknowledged this report ...such that it does not is trustworthy. He believed that in him there are shortcomings, and he also indicates this in in your report. So, I probably don't even I would say that this is intentional, but you know, incompetence is throughout. What? Yes. So, it's still worth it to consider regarding noise: he's not just annoying, but these are constant noise stimuli can significantly influence our health and life. There are decades research and systematic reviews that showed this connection between noise different frequencies, its permanent presence and that how does this affect general condition health. The most convincing the evidence relates to noise exposure from environment and transport—no so many data centers, because research there is no information about them yet, but I think we we will see this if let's continue like this growth. More so, remember the airports, when were they started build, about this no one thought. Now we see all these sound barriers that are trying to alleviate the situation, but still there is vulnerable groups population around airports that continue suffer. Yes. So, the first is health effects, or wrong? I think so too. It is worth mentioning that wildlife too suffers from this noise. These...these animals hear these high frequencies, and their sleep, behavior and reproductive abilities—all of these experiences negative influence. Do you have any more?
something about wildlife that would be useful for you? Yes, the Commission on wildlife resources nature of the North Carolinas published relevant document . We lead with them negotiations, because during our conversations we discussed this and understood that high-frequency noise will affect such creatures like bats, etc. And there are also opportunities something else. But they not found yet a lot of literature regarding low frequencies noises and how it is on will affect them. However, we asked them to provide any research or materials that show how this constant 24/7 noise will affect them. We let's consider their brochure or document, which they provided in within the scope of this issue. And their recommendations at this moment boils down to, to ensure acceptable buffer zone and environment existence for these areas. I don't know whether this is enough, after reviewing what do in others places only for minimizing the impact on people. I believe that because some of our furry ones more neighbors sensitive to such things, these zones, maybe it's worth it increase or continue them study. I think that with the emergence of new research we we can do better resolve this issue. The other day I read an article, which stated, that there is more research that document negative impact on wildlife in the world, than on people, at least in relation to opportunities installation correlations. I can find a lot information regarding light pollution. And I have meaning that many research negative impact is carried out precisely on animals. Yes, a lot such medical research actually are held on animals, and then... Yes, of course. No. So, you have laboratory means conditions compared to wildlife? Honestly, I don't I know exactly how they are. conducted research. But this there was a discussion about various studies that were held, and about their impact on wildlife nature. They can better to document impact on animals than on people because
much easier isolate research on certain representatives wildlife than about people. And there is one study, link to which added, where it was said about the old factory with methane pipes, and they conducted an assessment health status, therefore what people reported about all kinds of symptoms and the problems because of it, and also because of the noise, and they concluded, that is difficult to track the reason when you are you in open environment. For example, we do not we know what these people are up to encounter in others places. But significant part of the research is held on laboratory animals, and they can in a certain way extrapolate this information. Yes. Ahem, there is a lot of things here, so we have provided you many links and quotes this time. You not necessarily view them all, but if you want to get acquainted with some, they are very meaningful. Some meaningful connections found between environment and noise. The spectrum is wide: this is cardiovascular disease, and increased blood pressure, different types of problems with mortality, diabetes, hearing impairment, neurological consequences, as well as other hormonal and reproductive problems that I also seen in some of these research. It really interesting. AND, definitely a little It is strange that in society was not more talk about general noise, but as I already said, we provided two pages from research. Some of them were provided employees, and some—residents of our community, which thought it was worth it to share, and I think that there were enough qualitative research. So we will share them with you. All of this will also be on website, and we we will send you this later in the appendices to email. Here is the section about the wild nature. So, how do I already said, software proper buffers zones and indents—this what they really are recommended for habitat . Here they offer, for example, support natural buffer of 150 feet around the water- wetlands and
other important places existence. They really pay attention a lot of attention lighting, that is minimizing the impact artificial light. Ago it is important to add lamps with shielding, perhaps, use dimmers, turn them off etc. I think we we'll see from them more information, because data centers are starting en masse to appear in North Carolina. I I will continue. to follow others jurisdictions to to see if they are considering this question. Unfortunately, with data centers on current topic mostly human-centered, but I believe that there is an influence, and I I can't really hear you. So, there are two pages. You will also receive this document. Of mitigation consequences, we discussed how previous codes considered A-weighted measurement for norms noise and tried balance it out. AND now we are talking about adding C- weighing so that we could catch more those low frequencies and to see what the AA scale passed there is also a Z scale, which actually it's simple unweighted scale. So, he is considering they are all here to just to see what exactly filled with noise, which is created on a certain frequency. Therefore, in some ranges 1/3 octave this looks like approximately like this. It also provides a little more detail. So, you can to see what the noise is generated here, creates a lot decibels in range from 250 to 400 Hertz. He also generates some noise in range of 40 Hz, but more—in the range 4000 Hz. But it gives you a better understanding of Where does the noise come from? instead of simply to focus on range 250 or from 250 to 1000. Sometimes review of indicator A is effective, and sometimes no, depending on use and type product or activities. So we talked to an engineer who works mainly on a big company. I am not I will call theirs name, but he has a lot works, and we discussed with him, how to try minimize this if the city council still wants to see this use, or any other industrial using. He strongly advised we use noise barriers,
acoustic blinds and things like that, so try soften the sound. They should be as close as possible closer to the source sound. Remote the walls make a lot few, and they are not like that effective. And the sound can travel and to bypass them. There are different types of barriers. THERE ARE reflection barriers, which, in my opinion, they do us bad neighbors, because you take the noise, repel him from walls and, in fact, sending somewhere to another place. I think this is an easy solution for many people, because they, probably can get the necessary measurement at the border of his own plot, but who knows what this is causes further, and this will become a problem someone else because several years. There are also absorbent walls or walls with absorption. These walls filled with different materials, therefore they are partially capable to catch noise. So a smaller part of it able to penetrate further and go beyond. There is diffraction, which, again, breaks the sound into different zones. So small his part is scattered in many different directions. This reduces intensity. AND finally, distance is always powerful means. Sound waves, which are impossible to repel, to absorb or to subject diffraction, you can to solve only by source separation noise from sensitive objects. Um, part infrasound, sound lower frequency, has longer waves. They can bend. They can bypass noise. They can pass through different things. Ahem, and therefore sometimes efficiency noise-proof barrier really depends on many factors. So, the advantage is that if, say, we have industrial facility and we spend all these test or we demand from them provide simulation, and we saw that low frequencies more than expected, we would knew that perhaps some of these walls, like- Is that a reflective wall? something like that, maybe not be the best decision. Perhaps, will need consider others options in progress. Hmm, advantages noise-proof barriers. So, they really can help reduce noise pollution. Um, thanks to this can be improved health and well-being of neighbors nearby and even employees. Nobody stops to to think about employees. I know, that it is difficult to sympathize, when you get paid, but, um, I visited several objects industrial use, and I really developed some empathy for people who have dealing with noise, smells or things like that. Ahem,
this contributes to the aesthetic attractiveness. You are not you see so many of these noise sources. I don't know as far as these are more attractive boxes and I'll show you a few photos the boxes themselves, but, um, they look a little differently. And also, um, there is some influence on environment if you maybe you can add some green infrastructure or noise barriers. We'll talk a little. about how to rely on planting and greenery noise barriers, per minute. Therefore, transmission lock sound. Um, this is taken from, um, this table here is from Federal highway management roads. And she just breaks down materials and approximate transmission value and sound loss for common materials . So, you can see how it is broken. There is here material thickness, weight, and then total loss at transmission, um, sound, which is displayed. Um, we already talked about it. about this. Block Infrasound is very difficult. Hmm, normal The soundproofing works. not so good. There is many ways spread. Um, exactly. it will come in handy here consultant who can really to evaluate what sound generated, where it is spreads like it changes under influence surrounding environment and weather, and will try maximum protect sensitive objects in this area. So, it's simple. a few illustrations, which, in my opinion, worth considering. So, this is a chiller. Maybe you see fans on top, so the noise comes from fans and from below. So, their goal is was to try minimize the noise that generated by this device. And therefore one of the solutions that they used, — this is an acoustic barrier with sound-absorbing wall. These absorbent walls filled with different materials inside, so that help reduce and absorb part sound. What is the term? operation of one from such walls? Is there any on some of them are limited service life? I will have to find out for you. Yes. Um, service life usually enough long. Equipment will be replaced sooner than wall, but with this one The wall will become that,
that she will be "killed" during technical service, because no one will be to be particularly concerned . That is, they will be to crash into her, to push her, to hit her box with tools or spare parts. So eventually they become similar to industrial garage gate, into which several entered once forklift, and they broke. She saw better times, so over time they become less effective because permanent damage . This is wonderful. remark. This is one of reasons why a tree and other materials, which can crack or have a porous structure, also become ineffective . Yes, that's quite it. It can happen. Um, yes, and you will see on this picture additional coverage, which helps reduce noise from below. One problem, about which I read: when spend maintenance, they are removed and forget to put back. So, they stand first, and then they are not are returned to their place. And then again there is noise from this equipment. All these offers separate from the requirements for the equipment itself, right? Because you can you specify coverage and restrictions for equipment, but we don't we will discuss this is this year. No, we won't. We are not... So, that's it. a specialist who is engaged in sound modeling or plan noise reduction in within the scope of the amendment to video to determine the best approach. Because, in my opinion, one of our problems planning is in what we become too directive and we say: "You must to do this, although this is not the best option for them tasks. Yes. And thank you, Jay. And things really are changing. Hmm, this is just so that to help everyone to understand what exactly now is used. Ahem, so these are blinds that redirect sound . Additional walls, here shown only concrete foundations. What size is this? they can be both to look. More barriers, where thicker ones are shown jalousie. Acoustic pergola from above helps to reflect noise. We will see. an example of how this looks. So, in
to your presentation they provided data about what they were able to reduce the sound. Ahem, condition before installation —it is red here. So, you see, on frequency 80 it increases , and then on higher frequencies fall. Therefore, from 80 to 70 they were able to lower it approximately 8–10 decibel, using these means. What is important is that we saw all the different things that they did, all these different materials, and they are all we were able to reduce its only 8–10 decibel. So, there is a certain the limit of how much actually possible reduce noise. You you will see the pages products and descriptions, where they promise a certain decibel range. Almost never manages to achieve the highest level, which they declare. Therefore, Let's get back to this. Here is the big one potential for future development data center. Many buildings. You know, it doesn't look like That's bad enough. IN We have many reservoirs. On there is still a little bit of area vegetation. Around there are buffer zones. Problem. So, we We're talking about noise. See how they are close are located near the roads. Some of these areas have, maybe 75 feet or more than the existing one vegetation. From mine conversations with experts from sound, vegetation actually almost It doesn't help. This must be land. It must be real strong materials on sound path. And therefore, if such a thing comes plot design, we we can think: " Okay, they provide all these good things." They don't destroy much. the environment in that are left in place. We must be very attentive, working out the details and settings regarding proximity, as well as how we we are going to do this to soften. If there is area that can to be limited by size, and the area where the distance is shorter, we it is important to have standards minimal distances to sensitive users. Therefore, this is just one of examples of this kind. It's simple. example of reduction by by law of the inverse squares. So, in distance from sound sources you you start to notice
sound reduction pressure. That is, in decibels. So, obviously the further you go leave, all the more decrease observed. It again confirms importance correct keeping distance . And then it remains to walk along document that is before you, line by line. I want to stop and to find out if there are any question. Probably, we will have a lot talking about it, and if we won't have time for everything today, this normally. We still have time allotted for project preparation. Preliminary schedule based on 1000 feet , you said so, regarding distance? It must be feet, I I think. They haven't yet provided data. I think it's 1000 feet, and it's will reduce the level by 60 dB. Maybe it's meters. I I have to check this. Sorry. I thought, this was indicated on the graph itself. Good. It sounds like, like and with air quality, the distance is not too far important. Distance, distance to keep people safe and animals. Yes. I think we are very we know each other well engineering, and once someone will invent something, that will really help, but the increase distances really useful. I have one. questions about indents. We could indent 2 miles. Mhm. But if noise can be 60 dB, let's say, on the verge property, But doesn't really have importance, how much This is a big digression. Yes. But it has Mhm. If you They can create how much any noise, until until they reach property boundaries. Yes. If you want go to section Let's start with the section four. So, this is a bit
differs from that we may discussed earlier. Um, we were talking about level measurement noise, perhaps on the verge of areas, and probably this would be the way forward. But, um, after talking to residents and having looked at that are trying to do in other places, um, some of these ideas actually taken from legislation, proposed in House of Representatives South Carolina. So I thought that this interesting. Um, so, first—they have provide a plan mitigation consequences. Um, one of points is to because they have to show land use each area in radius miles. Um, they must show prevailing winds, temperatures, inversions and all something like that, maybe to influence sound propagation. Ahem, in addition, on page, I don't have it right now. But she I have it disassembled. There is a section under called "points". Okay, "points" compliance". Thank you. Here it is. Hmm, this is still in the fourth. This, this starts with point D. Compliance points . Mm. So, here they are four. Um, the first one— at least one of certain points has compliance to be in the direction of the border protected area, that is, sensitive user in radius of 3000 feet. Ahem, there is no maximum. The city can to appoint more, if there are any problems with noise propagation and the appearance of complaints. Um, on boundaries of the object area, which goes to each protected area, for 25 feet from exterior wall the nearest residence or object sensitive to noise. Um, us too we can install other places for measurements that are worth to consider for solving such problems. I think that just "patch" it along the boundary of the plot the easiest, but I don't I know if this is appropriate in this text. It also requires installation
permanent system monitoring. Hmm, what would help remove some of the concerns, as for me, regarding necessity permanent departure staff for measurements to which they may not prepared. While , having continuous monitoring that works properly, you can you send this information to the expert for analysis, and they will be able to provide a report and maybe some advice, how to reduce this impact . Um, so, the need to real to take into account noise pollution on larger territory than the boundaries of the plots—this, It seems that what you It's bothering me, John. Like, Yes. So, I think Well, I mean that I was somewhat surprised: if we measure noise level at the border areas of the object. Uh-huh. It seems that if we we are trying to reduce noise, and the building located quite away, then noise on the site itself may be enough loud. True. And then. This can create others environmental problems, especially, you know, in in the air, and. Ugh. Yes, but also that Where exactly is it located? equipment, will have very important. I think it's much harder. minimize noise from equipment, installed on roof. Just for the sake of review on how it spreads sound, and especially because that there is almost none obstacles to the wind. Hmm, you're right. noticed, and I think, What exactly is going on here? our conversation, because we are not we understand that when we see 60 decibels on counter on the edge areas, we believe, that everything is fine. We are not we understand how is spreading low-frequency tonal noise. And he spreads a lot further and really affects on people's lives. You you can make sure in this, if search on Google lawsuits and similar things, related to this. Often those who are now are on trial stage consideration, mostly
I would said, doubtful cryptofarm, because they just mock their own neighbors and don't know how to to behave with them. But I think that in moderation how data centers will become more and more bigger, we we will see new ones problems related to them. However, the noise, in my opinion, always will be a problem. Yes. Yes. So, regarding equipment that makes noise, right? Himself data center, and then these generators, diesel generators, they often spend their testing, you know, backup. Ugh. Verification, right? Or we see some specific rules regarding noise for these generators? Because they also have follow the rules. Because, you know, a generator there is a generator, no one It doesn't matter, right? But we still have some rules regarding this. The project has provisions , which requires them providing simulation for full built-up and working condition. It means that we want to see all your fans, all yours coolers that working simultaneously at full power. We want to see, what a noise will generate your generators if you need will have to use them Um, this, this is the intention in in this case. It may change. Um, you you can contribute your contribution, but it was made to take into account, because you right: they are monthly will test their generators probably by different parties or groups, depending on size. And God forbid , it will happen. Limitation will happen until we are trying to build up generation and similar things. They will have to turn them on. And this is not must have to be diesel generators, if any possibility use natural gas, or if the company can to afford it, they can try use another type of storage devices energy, batteries or something else like that. Uh, me, me I know about the color.
roofs, are there any restrictions on this? You know, we green roofs are needed or something like that? It visual moment, I I know, it's not related. with acoustics. Can you repeat that? Sorry. Roofs, basically. There are certain regulatory acts. Uh, about the roofs in general? Colors, yes. Oh, and about the colors? No , but we discussed in planning in general, that we are part of another subcommittee on tree issues and the effect of "urban heat island", regarding painting roofs or use of different roofing materials, to help to soften some urban effects heat islands, etc. No, no, if there is anything specific, what, in your opinion I think it would be worth it. consider for roofs in general. From the politics of others places I have seen, I I think that's what I'm looking for. I can point out how link, based on what I read. Oh, of course. What, therefore, color Restrictions on " "cold" roofs and materials. Regulations prohibit materials with high reflective ability. Okay, yes. Of course. And this one glare on the surroundings. Okay, that's what they're about. they say. So, in order to prevent this, you know , reflective Did you say? And they too obliged to install greens roofs, vegetation layers or highly reflective " "cold" roofs, of course? IN combined with permeable asphalt for control high thermal exit and reduction stormwater runoff. So. So, I just read and thought, You know, it's simple. Yes, just curious, Where is this from? Uh-huh. I think this is part of it. one thing, and architectural and urban designer integration is really part I mean, I I love green walls and green roofs. I am for this, but I met this one great resistance even regarding installation solar panels on their roofs, what do I It's hard to imagine that they will agree to place any there what type of living thing organic material. I think it's green. the roof works best, when there are no hard
structures that block it, you know, I want to have homogeneous vegetation. And he should be relatively equal, so that you can was to serve something like that. And if we speak about something more than just small data center, I think you have problems will arise with …One of the questions regarding this green roof, which one are you talking about —this is wild nature and possibility of it using. And I think , they will have a hard time because the noise coming from there. AND through the vibrations of itself buildings, you know. It would be interesting. see how feels vegetation on those roofs under such constant influence noise and heat. Although they love the heat, but And permeable coverage is included general requirements of EAB, or there are certain provisions, which we can to note. They must do this, but will they? I don't think anyone else agreed to this. Which is absurd, because it not difficult at all. No, that's not it at all. difficult. Our company did it. in Virginia, we have building with status LEED Platinum, and previously it was it was terrible abandoned place, so we had to demolish half of the parking lot. Now everything will penetrate, it collects all the water. They didn't have any problems, and in fact This is great because every time, when I arrived in office, it was raining, and I could to go inside, not stepping in puddles, and my shoes are not got wet. I don't know. There is some strange stereotype that I will have to do this serve. Ordinary concrete is good. You will go to the beach, there are impenetrable everywhere road surfaces, Yes. there is plenty of it.
I think they are getting easier. to clean. People develop various machines that allow to support them in cleanliness. Yes. Isn't this new? technology? So in just for a moment will have to accept with this. Yes. Yes. So, let's let's go through it briefly on this. We used to talked about the presence of levels. Levels and general load for this can change and to adjust accordingly how we let's learn more and, maybe we can communicate with other experts industry, but for illustrations and further movement we divided them into three equal. We already said earlier that, perhaps each of these levels will require additional requirements for area. Therefore, that's about it We will move on. Once again, if we have section without segmentation, then level is determined general connected load at complete completion construction of all phases and all the buildings under joint ownership or control over neighboring areas. So we try prevent the situation, when they build one thing, and then coming in 2 years, not knowing what will be further. Or will stay there loopholes, but we we are trying this minimize. Another one thing that I am doing now I notice it more often, no failures through private agreements, therefore no deal, easement or concept between operator and any by which owner real estate, tenant or government does not increase the limit and does not reduce indents, provided for in this articles. Perhaps, legal department will delete this when will review, but Essentially this means that you you can't buy exception. Because, perhaps, at some point another one will appear property owner or other purpose, whatever they want to introduce, and so further. It Are there any differences in norms for the first, second, third level? I I want to know what we are we can, you know, allow, what not we can. I don't. I know. Yes, yes, no, everything is fine. . We haven't shared yet. none of these formulations. We talked about it previously on another meetings, but they will be. So smaller equal—it will be kind of smaller objects. So, on the site will be fewer generators and
cooling tower. They will have certain basic standards, for example, noise, probably will be an important factor where they don't care will have to reduce the level noise, but perhaps in there will be fewer of them indents for such things or others elements. Yes, it is. will change, but for higher levels, for these larger objects, there will be much more restrictions. So here it is some definitions. Here . We will analyze the sound, night operations, sensitive users, operators, credit properties, I will explain third octave band general sound. Urban acoustic consultant mentioned enough often. This is an independent acoustic engineer, which one chooses and hires the city, and payment is made from the funds provided the applicant or operator. The consultant does not should have to work for applicant, operator or their branches during the previous 3 years. Again, this will probably be changed or corrected. I am not I know how easy it is. now in this field find an engineer who not at anyone worked. Yes. Um, it's pretty simple. Oh, really? Good. Um, there are companies that specialize only on the move testing. For example, regarding compliance requirements. Of course. and so on, and also regarding the part that concerns compliance with regulations. Um, and , to be honest, most people not really are concerned about this under design time. It of those things about which they write, we we assume that everything okay, and then problems arise later. So there are companies that can do it. Ahem, and I think that they, probably enough, so that you can even change part formulations, where, maybe you have deals with several of them. Mhm. And thus, if they will say, they say, work with this, we have there are two more to choose from. And this gives you a little, you know, flexibility. Yes, because I don't think...I I think that a lot data centers are made design is not for with the help of local engineers, and on national level.
So they will have either someone in the state, or they will work with the national by the company. So small business and companies around Raleigh, which this are probably engaged in would be happy to consultants and received a project for implementation. That's good. I, yes, I I appreciate the idea of having possibly variable a list or something similar, because there is different sides, yes. Um, regarding using, sensitive to noise, I I see, at least in this one paper version, which "environmental protection" zone" is specified in brackets. Oh, because everything in brackets is, probably what open to change or edits So, nature conservation area ...I want to talk. more about this: or will these be special conservation areas resources according to UDO, will this cover more, like habitat , recognized biotopes or something like that. Therefore, now it's simple nature conservation area , but she can to change into something more specific. Good. We have already spoken in past presentations about the conduct various studies noise, etc. Like this previous modeling to to get an idea about what the background is like or current noise on area, and then understand how object use will influence him with his additional noise. Ahem, this is what I think we must preserve and have. The only change here is that instead of a requirement conduct research after construction, you have ongoing research , which lasts from from the very beginning. So you just constantly collect data, and if something arises, you have opportunity to contribute changes. Hmm, that might be it. become financial obstacle to some. Unfortunately, I don't I know how much it is. costs, but it's for smaller landfills; maybe they need not as much as, let's say bigger objects where has to establish meters everywhere in different zones. So, I think this is must be continuous. I think this is an opinion. many people about these larger objects, Yes.
So, I just want to to clarify. So the points in brackets can to change. Things in brackets, probably will be to adjust. You you will see, because there are some things there, for example, distances in 3000 feet or something like that, what will probably happen changed, or restrictions on size, etc. Although this, probably will be changed during discussions with you, and also with others departments and experts. It's simple. areas that we have to discuss. Yes. So if you see in in brackets something that causes you question, let's do this let's discuss, because it is That's what we're here for, yeah. Good. Yes. And then there will be the final version where these numbers will be recorded. Oh, you, you will have, yes, you guys, will you... Okay, and then we, good. Yes, this, this, this is ours first look at this. She was very polite. recommendation from one of the residents: because two of our members leave council in January, it would be it is useful to provide you any text, even if it is draft version. And in this was the goal— start working on this , having received your reviews now. AND move on, but, of course, we have to make time directly on writing, but we we don't want to lose possibility to chat with you, if anything will arise. Does anyone have some...I know, here a lot is needed review. Is there some major, big ones concerns about noise, about which you could to tell, and which ones, maybe mentioned there or not mentioned? What comes to mind.
Number eight, noise reduction, evidence justified expectation. It It doesn't seem very... What number? Hmm, I'll take a look now. AT. Let it be C8. Sorry. C8. What section? Four. What is...What would be proof justified expectation? Ahem. I think it would be every intention, for example, to pass because of everything that required in chapter six and other sections, and show that you adhered to this the rule itself. What are you provided by all measurement and things like that. Um, I I think it's about what we are looking at. It's like an intention. It's like me I don't think there is one here. intention, as it is written, give them something else, than a reserve of three decibels, which is like below the ninth point. Um, that wasn't it. as if you were doing your best tried to prove, who could do this to do, but not you can go down below 10 decibels over the limit. This is not intention. I think actually worth it a little more emphasize and rate point nine that you can be on three above, we are we understand, but you did everything possible, to achieve the intention, and this is a deviation allowed. It the wording can change, of course. Is it defined somewhere? your protected property? Mhm, in the definitions. Oh, oh. And then I'll scroll up to this. Where did these come from? sound restrictions in chapter six? Sound restrictions were taken from several They were They were under the influence of several sources from which they took. Hmm, new district ordinance Prince William regarding sound, they took it from the proposed bill South Carolina, they took it from noise ordinances oil and gas industry Colorado, which they have specifically for
this. Um, some of them in the table you you will see, daytime and night time, um, for, uh, C-weighted decibels, they are in brackets on level 60. I think it's number This number is exact will change and will be vary. Me just need to talk to someone, who has a little more experience about where it should be in this line, because on I am not at the moment. I know exactly how it should be. to be agreed upon. My concern is that some of them are very high, and there is a sharp difference between designing for equipment, industrial equipment that is not continuous, compared with continuous noise something like the center data processing, therefore that even industrial equipment, very little there are things continuous, and the influence of this noise. AND you know, if you said: "Hey, our data center will be industrial." He may be on Level 80 all day, 24/7 . "It affects your hearing is much greater, than if it were 80 and lasted for hours. And these numbers tall, and as an engineer, to whom they addressed people with complaints about chillers at school on the neighboring area, I I can say: we measured, and there were 50 . I can only imagine, if we have a date- center with 15-20 chillers, How loud is that? will be for everyone constantly. So, decibels in tables one in Chapter six—this is for receiving side. That is, it would be, let's say, how industrial facility next to another industrial facility. It still could be high rate, and That's fair. But this would not mean that they would be allowed create level 80 near the school or something like that. It was would be more protected user for whom the indicator is 55. Yes. Well, I saw something from SolarCity, which Aha. have some things that I was impressed, nice. impressed. Their commercial and
industrial land have higher rates. They have a different category. They are open from 7:00 a.m. to 10:00 p.m. evening for industrial zones 65 dBA is set. Mhm. and 70 dBS. And then the indicators are lower, you know, from 10:00 pm until 7:00 am. Yes. Even for industrial zone, I I think it's a bit too much. Of course. No, I think it is. rightly. AT. So, regarding our testing: let's say people nearby, today nothing works, but tomorrow we want to conduct a test. Or the neighbors will notice level up noise because of our generators? Will there be Is it noticeable to them? we need to warn residents :"We are testing tomorrow, you will hear a little more noise than usually during data center operations "? I think Should we inform them in advance, for example: "Okay, we we will conduct testing in such and such day "? The document contains wording about necessity notify the city every time you use generators are not for testing, and in emergency situations, and you have to explain what kind of situation is this, to prevent similar to future. I think what's going on, and I I don't know what kind of city this is. decides, but I I understand your point. We won't be able to contact everyone owner real estate nearby and warn them that we we test generators at a certain time, likewise as a city without anyone warns when the siren goes off Harris. Today, probably, we can do Facebook post, so that no one is scared , but But Sharon Harris publishes They publish, yes, they publish. Therefore , I believe that the owner or user of the property must be good neighbor and to inform people. They must have commitment to promulgation
information. The city is not must report them, when exactly they are going to hold testing. This has be responsibility owner. And testing generators has to take place according to regular cycle, so it should be similar to tests sirens, for example: the third Wednesday of the month, at this time we We are conducting a test. Of course, except random natural misfortune or something, for which we cannot influence . But the city will be informed about testing. So we have this for, Yes. I think I'm somewhere. saw, but me worried about whether they will find out about this residents. Yes, they will be determined time frame when they can them launch, only during the day, so that it is not possible was to turn them on at night . Days seemed to pass about non-working days. Urban holidays or something like that. Was there an offer? regarding which distance center data processing has to be sensitive objects? I think they stopped at No I remember if it was 1000 or 1300 feet. Good. It was, it was something in that spirit. Planning Commission made changes to increase it. Of course. Hmm, I can do that. verify. I have this one is not available now information. Just curious how it is correlates with minimal indented here, in chapter seven. And again, they are in brackets, so I think that there is space for discussion, for example, that 500 feet for the first level—this is as for very small independent data- center, not definitely about what we said, like internal or corporate data- centers that are part of
another object. So this is kind of 10 here, for this first level, as if we are building small complex, data-oriented center. The goal is to so that, as in previous chapters, to conduct research and modeling on greater distance than we saw (3000 feet), to understand land use around and where are sensitive objects. But then you you see that indentation only the largest; for he is of the highest level was 1500 feet. Ahem, so, not even this, this only half of of what was. Hmm, but you know, it's simple a kind of departure the point where I think I heard how some people they say 500 feet— that's not quite enough. Um, 1000. Since we don't have such in place, let's go in a little further. Is there such a train? apparently, will exceed some standards, will it be reasonably? But this short-term surge . True. Yes. Yes. It it would be similar to pile placement various things. Yes. They worked 24/7. Yes. 7 miles from smelter. He also worked 24/7. I often visited that city, that's why I heard this noise on yourself. I think I grew up with this. I was certain. got used to it to some extent. You know, I didn't know. nothing else. Unless that low hum smelter, it could have been...This it was...i don't know how far away it can be was heard. But he was quite constant.
Imagine. Do we have any dates- centers nearby, and whether we visited them ever, or environmental council? The Environmental Council does not did not carry out any trips or something similar together. Maybe they were driving. independently. It seems Melissa could to visit one under time of your travels. Hmm, she probably is. can you tell me about it to tell. Um, but we did not carry out no large-scale trips to date- centers to really understand the situation, maybe we had to would go quite far . Hmm, so I'm not sure. regarding logistics, but if you are traveling, I can try. find a date for you- centers, and you will be able to add them to stops on Google Maps. Yes. Yes. Yes. Yes. Ahem, there is nothing nearby really significant size. Hmm, but there is a few in Charlotte and larger ones in Statesville. Yes. And then... Statesville. Statesville. There is facility in Maiden. The Apple object is really great. Hmm, but there, except for cows, nothing no, so it's not... I have a friend who designed several for Google. I will ask. Yes, that would be helpful. . So, I noticed something in transport report, which reminded me of this is about vibration. Or create data- centers usually have this vibration? It's not like a train, but it is vibration that generated from fan operation, and if they work generators, then There is definitely vibration. Yes, therefore, potential vibration is possible. Here where is the distance helps in this, but... Okay, yes. The equipment must mother, and this is what can be to determine, but can make vibration isolation for all equipment. It quite difficult {slash} expensive, but you know, especially external equipment, because it everything is on concrete base, and this
vibration when you add the number, she Yes, and that's why you can actually ask to install them spring concrete stove top main it's like it's lifted platform made of materials that help to soften it. And vibration usually quickly dissipates, does it depend on soil or Usually enough quickly. Of course. And that's why we do this. for everything equipment in the building, because it is transmitted through solids surface, but with this Everything has soil on the outside. to be enough Of course. she stays on place, but again Yes, that's a lot. equipment, and when everything vibrates if everything works on one frequency at the same time, harmonics will make the influence is stronger. True. So I noticed, what does it say: date- the center should not create a ground the vibration that a person can feel without devices in any point of another property. They probably don't will be. Of course. I wouldn't feel that way. They have a problem. Yes, that's exactly me. did. This was added due to concern residents. And therefore, if someone will say what he feels vibration, this will enter the system complaints, and it will be necessary mandatory repeat testing. Of course. So, if they replace equipment during maintenance, or we need to conduct testing from an acoustic point of view ranges, from the point of view compliance with standards ? This is also an advantage permanent monitoring: replacement equipment anyway will be recorded, and we will be able to see, Are there any changes in the level? noise, are they still comply with the standards,
or exceed them. It excellent comment, and This is where I hesitate, trying to find the best way for measurement, because equipment undoubtedly will change. It may become more effective. It will be better. It will be quieter, but this it could be worse equipment or other equipment that has other properties. AND so if we are too harsh regulate type body or mechanics, we're going to miss something. What? Yes. So someone forwarded it article for subcommittee on new technologies cooling. Well, if you create specification wrong, you eventually become dependent on each other supplier technologies, and this ethically you shouldn't to do this with engineering point vision. Engineers will to argue with you regarding this. Developers will about this. So you just You could you We can't should say that you obliged use a certain technology. We should just to establish that this basic indicators efficiency. I agree. Uh having having standard a certain type of grass, you Well, that's your job. boys. Have we considered ASHRAE standard 90.4? No, because I don't have one. access to this manual. I can't I I can't get to access to it. Do you want me to do it? purchased? Oh, I would I don't want that someone bought something, but It's okay. Em Well, we are left with some money in budget. I mean, give me let me try to contact. I I have If we if we need to buy this, it costs $178. Um, but I have my own opinion. such that it is probably it would be great Certainly. This is our base level.
, and then we decide, which should be higher than him, especially because who are smarter than everyone else People have already taken us all research and wrote this. I agree 100% and I spent a lot of time in search of, um Free copy will not be. ASHRAE is very zealously protects his PDF documents. absolutely accurate there is none free copy. I I can confirm. Yes. They also have a very strict rule, that their materials are not there may be, um, used artificially intelligence, so their cannot be distributed so. Okay, that's useful. know. Yes, therefore, download any which one of them documentation in AI illegally. Got it. If the council believes that these the materials will be useful, I am I will be happy to contact you. other people and I recommend this to us. get. I would I would like I would like to have it. I just I I think it would be I would recommend this, and I'm ready when we do this. we will get, read do this presentation. This is great. Thank you. I would recommend this. Certainly. Try to get it. Yes. So, if you don't you know, 90.4—that's ASHRAE standard for efficiency of centers data processing. It branch of ASHRAE 90.1, standard efficiency commercial buildings , which is written as code. So, um, for example, Northern Carolina uses international, um, energetic I can't remember the name. But this energy code IECC 2015. Um, and that means that is possible use ASHRAE 90.1 2012. So he's a little outdated. Um, and that's why ASHRAE decided that we a standard is needed just for centers data processing. Therefore, they wrote document about energy efficiency, based on current level technologies, about what should it be minimum level efficiency for everything. I haven't figured it out yet. deeply, but usually there are sections, related to sound, and also the issue of water, electricians, efficiency equipment, settings and
much more. They have separate recommendations for HVAC systems, systems cooling, as well as separately for date- centers, which actually That would be great, I have to do it. So, yes. I heard yours. suggestions and I will pass them on this is for the management to to inform that we interested in obtaining access. Maybe someone in another department has access, and they could allow me to get acquainted with their a copy so that it was not considered theft. In their presence. So, we heard a little bit about people who produce their own electricity before connecting to networks. Uh-huh. If this Is that really true? will apply all this to this equipment? All this will be apply. OK. Because they measure sound for the object, yes, they are used. I thought it was 50- megawatt plant, more than 50 and above, Yes? They produce own. They produce their own electricity. I'm not sure. Well, maybe. will have to have some extra sources. Yes. Especially if they are waiting for Duke will launch new ones generating capacity . Some places they bring generators or connect to gas pipelines or something else to somehow start working. We heard that there is no change , but at some point someone talked about small modular nuclear reactors. There is just haste. They trying to move as soon as possible and not want to wait 10 years in line. Yes, that's what they're up to. collide. This is the main conclusion. Yes. AT.
So, during humidity, right? At high humidity the sound will be stronger. Is that what it says? As weather affects sound? Changes are happening. because of the way the sound spreads in air depending on temperatures and relative humidity. I can't explain it. in details. Perhaps, The engineer would explain better than me, but In fact, it affects sound, where it is is located, how far spreads, etc. OK. A document will be added, hmm, link to which you will receive after this so that you can to get to know him/her more details. Um, I just publicly I admit that it was as if You know, waves spread in air differently than in water. Mhm. True. True. And this is it The higher the humidity, the sooner water appears. Got it. I apologize for that. could not invite an expert who would appeared before you. The ones I tried to attract as a source, unfortunately, there were no ready to come and to speak, um, out of professional point vision. But, um, if in some time for us will be needed to contact someone, it is possible that respond to additional questions or something like that. I always ready to turn to others people and see, Can we do everything? to arrange. And, um, just respecting time everyone, if, if it suits you, and you like opportunity to bet questions during review, it's great. I Glad to be here. If to any of you it seems better read this and prepare separate question independently, me, this too normally. Simply let me know what for you the most easy. Well, I think so. It is useful to walk around. this, but Yes, definitely. I just, maybe, I really want to read this. I have there may be some Oh, yes. thoughts. Yes. I know, sometimes on meetings I, I or very focused on conversation, or very immersed in document and Yes. So, is there a target their completion date all, like, uh Yes, we have targets dates set in calendars on
website. Um, so, we now we are ahead schedule. This, this is yours kind of a little attempt to get ahead of events. So Do you have time? view this and provide feedback. Hmm, yes. , we just trying to move a little faster, knowing, that two of our members are going to leave. I'll look into it later. moment. And this sent to electronically , yes, Alan? This will be electronic format. It will be so. Good. And, just for you, board members, I ready to share a Word document so that you could do comments and notes, if it's easier that way. The only thing we are talking about please don't do this this is collectively beyond outside the meeting, since there are open laws meetings that we must follow. And I noticed something about withdrawal from operation. Hmm, this is as if it means that no plan operation is not will be required? That is, if and when it will happen, will there be in this regard are determined any expectations? Exit plan operation, yes. For example, inventory everything that is on object, how they are planning to remove or neutralize hazardous materials etc. Yes, it will be. the whole process. Will this be required? as part of this? Yes, as part of resolutions or, probably, as a condition zoning. Of course. To change zoning, Yes. Good. And at the very end document you have there will be sample conditions zoning. This is just some things that we could consider. Everything that is not included in resolutions or what we we can't to provide through her, it may become zoning condition, if they agree. Hmm, I see that too. possibility of conclusion development agreements for large centers data processing, etc., where there are opportunities for cooperation with the city. So there will also be certain adjustments. IN
draft law South Carolina, um, the fines were very high, and I know that many people this very interesting. But I removed the amounts from your project, so that solve them later, until I get it lawyers' opinion on what is legal in North Carolina. But in the South Carolina proposed bill provided for fines from 10,000 to 35,000 dollars per day for violation, which is significantly higher than normal fines for violations resolutions. Per day? Per day. Unfortunately, this is actually not so big money compared to the scale of which we are talking. Justice for the sake of, if you don't finish projects on time, your daily the fine can also be very high, so this just an incentive to spend money and fix everything. Well done, Southern Carolino. I don't think it's him. already approved, but he was entered on consideration. Regardless of that, that they still don't have energy code written over the last 20 years. I appreciate dreamers, people like me. This is what we are we rely on South Carolina. Is there a general practice, how often they spend testing? Hmm, it's written here, Let's take a look. So, here we have listed test at introduced in operation. So still before obtaining permission for operation (CEO) the following are held tests, and then is carried out constant monitoring . Um, they report about any failures during monitoring. There are quarterly survey, as well as public reporting, therefore in the document stated that the city should be published monitoring data and inspection results . So, um, it says about monthly results, therefore the main goal is in order to create website where you can
will review, if we implement this , noise level and understand that is happening. Hmm, and more documentation management and things like that. You say that the operator has show records about technical service equipment within 5 years. This is what you do you usually do? No, that's me a little too much. persistent in gathering information. I mean, I I understand the data regarding noise. Hmm, I can't. to say nothing better about it. Well, they should have records about service, because it proof that they really watching the condition of the equipment. AND what will happen to equipment, if it is not serve? Then the compressor starts work strangely and incomprehensible, giving away different and crazy sound. And at least, if you have data, you you might say, "Well, you don't have it served you will have to do this fix ". Oh, okay, it's worth it. know. I don't know. Maybe you better on this you understand. Is this equipment always is it purchased immediately, or Is it on credit or not? leasing, or what? Is there any at all the reason why they should provide technical records service? No, um, but they must have...for they have guarantees confirmation that they him serve. Um, and many, especially these processing centers data, um, I don't know, or because of a small they have staff someone from workers for service, is it is given to outsourcing. And then in they will definitely be there records, because that's how they will exhibit bills. So, any who, who manages any- what object, must keep technical records service at least 5 years. they should not have ...I shouldn't anymore to have them. I just And this...and this should just Here is another requirement. Yes, it should be. easily accessible, especially now, because most people keep records online, using free or very cheap software ensuring that to know who and when what does. I...the intention was to so that if something it will go wrong, but they They say: "We do nothing." changed at work,
we don't understand why not we comply with the standards " . You know, we say: "Okay, we think that The problem is this." Let's take a look at technical service. AT, they did not conduct maintenance of this Yes They don't like this one. mandatory trigger at number one. Yes, this is, this is the number in brackets. So, this is Well, I don't This, this is just, uh, filler number. I, I can imagine how someone, or a group, or The district is playing it out. Yeah, I, I think, uh, other parties read number two and they will just think, what we don't need Yes. this is number one. But before you mentioned about civil penalties for violation in Charlotte or somewhere else. $35,000 per day, this is what you did they say? Uh, Southern Carolina suggested a bill that would , uh, had, in fact, fees 10,000, 20,000 and 30,000. We haven't decided yet. with this. We don't...Uh, we have, our legal department must confirm that we are legally allowed, which maximum for this. Of course. Because now 160 160D, seems to say that, probably if you have it not specified in resolution, it's about 50 dollars per day. Can be done maximum 500 or, yes, this, this is very little. Yes. Very little. And he, maybe it should be low, and then it will deprive law enforcement a significant part of the force, but the possibility to control everything it will help. This is not even will be displayed in reports. No, 50 dollars? No. I
I mean So, I see that there is restriction protocol noise level. Or do you foresee any restrictions if they are big water consumers? AND, let's say it came severe drought, and we we reach the point, when choosing between water for people or for the data center. Oh, of course. Um, we we were talking, we, we briefly discussed this is with Jonathan Jacobs. To us, probably will have to review it with him, to see what he can do, because I think it is was, uh, it was a certain the type of permission that they should get because of him, where is he may nominate others conditions within this permission. This is probably it would be that we don't could codify, therefore. Good. And that would probably be it's useful to have there. In, in this In, in, in, in the resolution. Oh. I, I have, I have to will have to clarify does he have it? perhaps. I mean that their permits and agreements are also binding in a different way, so that Yes. Uh, is there, is there? predictions about how much data- centers can be Interested in this? No, um, no. I, I, I also not familiar with conversations about economic development at this time moment, so I don't know , are they with someone communicate. That a single platform, who considered initial developer, was quite ideal with center view data processing, simply in view of his proximity to high-voltage lines and treatment facilities nearby. Um, with considering the conversations, which this council led in past regarding installation very large minimum area sizes and things like that, it restricts in some way
opportunities placement of centers data processing. Hmm, but in Epex, probably still there are territories, but we have running out of space. IN we are running out space for big object. And I still believe that you wouldn't want to have weapon next to this processing center data. Oh, because of hunting? Yes, hunting land. Yes, they are are adjacent to it. Um, they certainly can. to be random shots towards the center data processing. Yes. Wait, no. Certainly. So, one section in rules regarding which I'm not sure how. he will be accepted, it is E. Hmm, future development protected. Usually this is not so, that is, if you are you building a house or residential area next to one of such objects, this as if you had to know what you are getting into. Ahem, this is just the first one here step because we we want the most to protect everyone, but I understand that this can be changed or deleted. But, um, you know, we're talking about how we want to see development our community, etc., and, maybe we too we want to have protection for the future buildings. I would say yes, because what is it, you know, after all causes changes in land use. That's right. Yes, usually you get adjacent user or even sometimes because the road, and this is yours kind of undesirable user, or something, what prevents development the plot opposite yes, as planned, and so someone finally will come and rezone it probably also in industrial zone, and Mhm. and then you're like slow moving towards that the same problem. Yes. Yes, exactly. Yes. Therefore,
what will be next steps? So, the next steps are: um, you're welcome review and give me feedback regarding this information. Hmm, we will act. further. We will have, um, in ours will be ours next meeting with neighbors, our residents, next week, 14- th number, where I will collect opinions and feedback from residents and provide them you later. Hmm, ah then we we will prepare for next meeting month, which will apply public safety. We will call the fire department. service and police, so that they can speak out presentation. Um, no. I think they will have it. a lot of that need codify, but everything I will discuss what will happen with them, I'll try prepare for you drafts, and then we let's get closer to beginning of the stage developments. Um, I I will try to do it. this is as soon as possible for you so that you have a clear idea of what is proposed, and felt confident. In addition, when your deadline powers will end if you would you like to take participation as residents, to promote development and provide your proposals, because all of this will be broadcast in the future, you will be able to to watch and bet your questions. It there will also be an opportunity for you. And then in some the moment it will be made public discussion. Oh, definitely. Yes. I mean, this is open to public discussion on at each EAB meeting, if anyone wants to come and apply to the council on issues subcommittee. And before the way it will be accepted or something like this, it will fit for consideration planning board and city council. Good. M-hm. So, you can to express oneself in all these cases. And I I think everyone that would be appreciated. I am. Um, so, do you have any now some additional questions to Bruce? Are we something? missed? No, I understood everything. Good. Can we then finish? OK. We are closing. meeting at 6:29. Very Thank you, Bruce. No problem. Yes, I am very glad that You told me that.
M-hm.
Speaking at this meeting
Town of Apex's own rules for public comment — check them before you rely on anything here.
Agenda items (3)
-
1. Call to OrderProcedural
-
2.a Noise ImpactsBruce Venable, a Planner III, presents on noise from data centers to the subcommittee.
-
3. AdjournmentProcedural
Other recent meetings of this board
-
Thu, Nov 1912:00 pm
-
Mon, Nov 1612:00 pm
-
Wed, Nov 412:00 pm
-
Thu, Oct 1512:00 pm12 items
-
Mon, Sep 2812:00 pm